SFF8639TestAdapterUserManual(Preliminary)
Page|7
©2014WilderTechnologies,LLC
DocumentNo.9100034000Rev.A(Preliminary)
3. The8639TPASMAconnectorshaveflatsthatacceptanopenend1/4inchor
6.5mmwrench.Whenattachinginstrumentcablestothe8639TPA,itisrecom
mendedthatthe8639TPASMAconnectorsbemechanicallyheldandthetest
leadsbetightenedtotheequipmentmanufacturer’storquerecommendations,
normally5inlbs,usinga5/16inchopenendwrench.
Ifthetestsetuprequiresrepositioning,firstloosenordisconnecttheSMAconnectionsto
avoidtwisting,bending,ortension.
NOTE:Adropinsignalamplitudebyhalfor6dbduringthetestingof
achannelmayindicatethatacablehasbeenmechanicallypulled
freeofcoaxialcableconnectionsinternaltotheassembly.Thiscould
bedeterminedbycheckingifthecablehasanylateralplayrelative
totheTPA.ThiswouldonlyoccurwhentheTPAhasexceededthe
pullforceasspecified
withinthemechanicalspecification.Ifthe
cablecannotbereseated,thetestadapterwillneedtobesentback
tothefactoryforservice.
CAUTION6:IndependentlySupportInstrumentCablesorAccessories
Excessiveweightfrominstrumentcablesand/oraccessoriesconnectedtothe8639TPAcan
causedamageoraffectthetestadapterperformance.Besuretoprovideappropriatemeans
tosupportandstabilizealltestsetupcomponents.
NOTE:The8639TPAR(Device
TPA)issuppliedwithDeviceSupport
Adaptermaterialsthatallowtheusertoproperlysupportand
stabilizea2.5inchor3.5inchformfactordevicewhileundertest.
Figure16,laterwithinthisdocument,illustratestheinstallationand
atypicalapplicationoftheDeviceSupportAdaptermaterials.