SFF8639TestAdapterUserManual(Preliminary)
Page|12
©2014WilderTechnologies,LLC
DocumentNo.9100034000Rev.A(Preliminary)
CalibrationThroughDe‐Embedding
TheSFF8639HostandDeviceTestAdaptersarefullypassivecomponents.Therefore,
calibrationcompensatingforthelossesmustoccurwithinthetestinstrumentationthatdrives
theSFF8639receiverorlooksattheresponseoftheSFF8639transmitter.
The8639TPAshaveTouchstoneS4Pfilesfordeembeddingthe
electricallengthand
losseswithintheTPAuptotheSFF8639connectorinterfacepads.(ContactWilder
Technologies,support@wildertech.com
,toobtainacopyoftheS4Pfiles.)TheTouchstoneS4P
filesenablethetestengineertocompensateforthelastfourofthefollowingsixrepeatable,
systematicerrorsthatoccurwhenmovingthereferenceplane:
Signalleakageeffects:Directivityerrors
Signalleakageeffects:Crosstalkerrors
Reflectioneffects:
SourceImpedanceMismatchingerrors
Reflectioneffects:LoadImpedanceMismatchingerrors
Bandwidtheffects:ReceiverTransmissioninTestEquipmenterrors
Bandwidtheffects:ReceiverReflectiontrackinginTestEquipmenterrors
Theseerrorsarecorrectedoneachport.RefertotheInstrumentManualforinstructionson
theinstrument’sspecificdeembedding
process.
NOTE:Thereferenceplaneistheboundary,bothphysicallyand
electrically,betweenthecalibratedanduncalibratedportionsof
thecircuit.Everythingoutsidethereferenceplaneisconsidered
partoftheDUT.Anyinstrumentthatdoesnotusecalibrationorde
embeddingofthetestfixturedefinestheDUTasthetotalof
externallyconnectedcomponents.Ifthedeembeddingfile
isnot
used,allofthe8639TPAandassociatedcoaxialcables,aswellas
cablesconnectingtheTPAassemblytothetestinstrument,wouldbe
apartoftheDUT.
Nonrepeatableerrors,suchasdriftorrandomerrors,canbereducedbutnotcorrected.
Drifterrorsaggregateovertimeorwithenvironmentalchangessuchastemperatureshift.To
eliminatedrifterrors,performaninstrumentationlevelcalibration.
Arandomerrorcannotbecorrectedthroughcalibrationsincetheerroroccurredrandomly.
Random
errorsaretypicallyassociatedwitheithertestinstrumentnoiseortestrepeatability
problems.Reducetestinstrumentnoisebyincreasingsourcepower,loweringtheIF
bandwidth,oraveragingresultsovermultiplesweeps.Reducetestrepeatabilityproblems
throughtheuseofatorquewrenchor,again,byaveragingovermultiplesweeps.