Agilent Technologies, Inc.
Agilent Technologies, Inc. 59 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
Example of products’s response to out of specification COMINIT gaps:
Possible Problems:
NOTE: A products must respond by transmitting COMINIT within 10ms of de-qualification of a received
COMRESET signal (see section 8.4 of Serial ATA Revision 2.6). With this in mind, a test only needs to wait up to
11ms following de-qualification of COMRESET to ensure that the products is responding. If no COMINIT is
received in this timeframe, this is considered a failure by the products to this test.
NOTE: In a case where a products supports Asynchronous Signal Recovery, it is possible that a products may
transmit COMINIT pro-actively and not in direct response to a COMRESET. In verification of this test
requirement, it is essential that the tester be able to extract any COMINIT response which may be as a result of
Asynchronous Signal Recovery, and simply verify COMINIT responses as a result of COMRESET receipt from the
products.